Spectrographic analysis of Iopa module #00001.
Spectrographic analysis of Iopa module #00001; spectrometer's response narrowed
to a band between 650nm and 660nm.
As you can see, the peak wavelength is ~657.05nm,
and the spectral line halfwidth is ~3.00nm.
Spectrographic analysis of Iopa module #00004.
Spectrographic analysis of Iopa module #00004; spectrometer's response narrowed
to a band between 650nm and 660nm.
As you can see, the peak wavelength is ~655.05nm,
and the spectral line halfwidth is ~2.10nm.
Spectrographic analysis of Iopa module #00005.
Spectrographic analysis of Iopa module #00005; spectrometer's response narrowed
to a band between 650nm and 660nm.
As you can see, the peak wavelength is ~657.03nm,
and the spectral line halfwidth is ~2.02nm.
Spectrographic analysis of Iopa module #00006.
Spectrographic analysis of Iopa module #00006; spectrometer's response narrowed
to a band between 650nm and 660nm.
As you can see, the peak wavelength is ~656.40nm,
and the spectral line halfwidth is ~2.48nm.
Spectrographic analysis of Iopa module #00007.
Spectrographic analysis of Iopa module #00007; spectrometer's response narrowed
to a band between 650nm and 662nm.
As you can see, the peak wavelength is ~657.01nm,
and the spectral line halfwidth is ~2.75nm.
Spectrographic analysis of Iopa module #00008.
Spectrographic analysis of Iopa module #00008; spectrometer's response narrowed
to a band between 650nm and 660nm.
As you can see, the peak wavelength is ~656.70nm,
and the spectral line halfwidth is ~1.22nm.
Spectrographic analysis of Iopa module #00002.
Spectrographic analysis of Iopa module #00002; spectrometer's response narrowed
to a band between 650nm and 660nm.
As you can see, the peak wavelength is ~655.50nm,
and the spectral line halfwidth is ~0.98nm.
Spectrographic analysis of Iopa module #00003.
Spectrographic analysis of Iopa module #00003; spectrometer's response narrowed
to a band between 650nm and 660nm.
As you can see, the peak wavelength is ~655.05nm,
and the spectral line halfwidth is ~1.10nm.
Spectrographic analysis of Iopa module #00010.
Spectrographic analysis of Iopa module #00010; spectrometer's response narrowed
to a band between 650nm and 660nm.
As you can see, the peak wavelength is ~655.12nm,
and the spectral line halfwidth is ~2.20nm.
Spectrographic analysis of Aixis module #00009.
Spectrographic analysis of Aixis module #00009; spectrometer's response narrowed
to a band between 645nm and 665nm.
As you can see, the peak wavelength is ~651.50nm,
and the spectral line halfwidth is ~2.80nm.
Spectrographic analysis of Aixis module #00017.
Spectrographic analysis of Aixis module #00017; spectrometer's response narrowed
to a band between 645nm and 665nm.
As you can see, the peak wavelength is ~651.90nm,
and the spectral line halfwidth is ~2.80nm.
Spectrographic analysis of Aixis module #00020.
Spectrographic analysis of Aixis module #00020; spectrometer's response narrowed
to a band between 645nm and 665nm.
As you can see, the peak wavelength is ~651.55nm,
and the spectral line halfwidth is ~2.70nm.
Spectrographic analysis of Aixis module #00033.
Spectrographic analysis of Aixis module #00033; spectrometer's response narrowed
to a band between 645nm and 665nm.
As you can see, the peak wavelength is ~652.95nm,
and the spectral line halfwidth is ~1.15nm.
Spectrographic analysis of Aixis module #00064.
Spectrographic analysis of Aixis module #00064; spectrometer's response narrowed
to a band between 630nm and 670nm.
As you can see, the peak wavelength is ~652.00nm,
and the spectral line halfwidth is ~1.90nm.
Note the broadbad emission, indicative of damage at the atomic level.